For Drum Jamming

Open all air supply/ash/coal inlets; stop coal feeding and feed conveyor.

Prize the large gear ring while jogging its motor to restart the drum. Shovel materials at the discharge conveyor outlet promptly.

If still stuck after ~10 mins: Spray water into the furnace to extinguish embers, keep prizing until the drum rotates.

Never shut down the fan, discharge conveyor or air lock.


For Drum Fire

Open all air supply/ash/coal inlets; stop coal feeding and feed conveyor. Shovel materials at the discharge conveyor outlet promptly.

Spray water into the furnace to put out the fire immediately.

Never shut down the fan, drum, discharge conveyor or air lock.

After removing all burning materials: Keep the equipment running for 0.5-1hr. Shut down only when fire is out and drum temp <50℃.

Post-shutdown: Monitor for 1-2 days. Restart only when no combustibles remain.

相关内容

Rotary Dryer ...
Regularly check for belt conveyor...
2025-10-11 11:40:23
Emergency Mea...
For Drum JammingOpen all air supp...
2025-10-09 10:15:15
Precautions f...
The dryer operator must always pa...
2025-10-07 11:44:44

热门资讯

How To Maintain... Way to Maintain Pellet Machine
Efficient pelle... Efficient pellet mills Advantages to make wood pel...
The reason for ... The first reason for the black pellets discharged ...
Advantages of t... Advantages of the Flat die Pellet Machine for Maki...
How to Make Woo... pellet machine and pellet production line
Is Flat-die Pel... Is Flat-die Pellet Machine Fit for Making Wood Pel...
Common Reasons ... Common Reasons For High Powder Content In Pellets
Advantages of B... Advantages of JNSHARE Biomass Pellet Machine
What is RDF, an... What is RDF, and How Does the RDF Pellet Machine M...
Safety Issues i... Wood pellets have become an important player in th...